IFM_201703 l - page 10

vol. 6 3/2017 Inżynier i Fizyk Medyczny
132
artykuł
\
article
radioterapia
\
radiotherapy
8.
U. Oelfke:
Magnetic resonance imaging-guided radiation therapy:
technological innovation provides a new vision of radiation oncolo-
gy practice
, ClinOncol (R CollRadiol), 27(9), 2015, 495-497, DOI:
10.1016/j.clon.2015.04.004.
9.
J.J.W. Lagendijk, M. van Vulpen, B.W. Raaymakers:
The develop-
ment of the MRI linac system for online MRI-guided radiotherapy:
a clinical update
, J Intern Med., 280(2), 2016, 203-208, DOI:
10.1111/joim.12516.
10.
A.J. McPartlin, X.A. Li, L.E. Kershaw, U. Heide, L. Kerkmeijer,
C. Lawton, U. Mahmood, F. Pos, N. van As N, M. vanHerk,
D. Vesprini, J. van der Voort van Zyp, A. Tree, A. Choudhury:
MRI-guided prostate adaptive radiotherapy – a systematic re-
view
, RadiotherOncol., 119(3), 2016, 371-380, DOI: 10.1016/j.
radonc.2016.04.014.
11.
U.A. van der Heide:
MR-guided radiation therapy
, PhysicaMedi-
ca, 9, 2016, 32, DOI: 10.1016/j.ejmp.2016.07.284.
12.
A.J. Raaijmakers, B.W. Raaymakers, J.J. Lagendijk:
Experi-
mental verification of magnetic field dose effects for the MRI-
-accelerator
, Phys Med Biol., 52(14), 2007, 4283-4291, DOI:
10.1088/0031-9155/52/14/017.
13.
Meijsing, B.W. Raaymakers, A.J. Raaijmakers, J.G. Kok,
L. Hogeweg, B. Liu, J.J. Lagendijk:
Dosimetry for the MRI acce-
lerator: the impact of a magnetic field on the response of a Farmer
NE2571 ionization chamber
, Phys Med Biol., 54(10), 2009, 2993-
3002, DOI: 10.1088/0031-9155/54/10/002.
14.
K. Smit, J.G.M. Kok, J.J.W. Lagendijk, B.W. Raaymakers:
Perfor-
mance of a multi-axis ionization chamber array in a 1.5 T magnetic
field
, Physics in Medicine and Biology, 59(7), 2014, 1845, DOI:
10.1088/0031-9155/59/7/1845.
15.
K. Smit, J. Sjoholm, J.G. Kok, J.J. Lagendijk, B.W. Raaymakers:
Relative dosimetry in a 1.5 T magnetic field: an MRlinac compatible
prototype scanning water phantom
, Phys Med Biol., 59(15), 2014,
4099-4109, DOI: 10.1088/0031-9155/59/15/4099.
16.
A.C. Houweling, J.H. de Vries, J. Wolthaus, S. Woodings,
J.G. Kok, B. van Asselen, K. Smit, A. Bel, J.J. Lagendijk, B.W.
Raaymakers:
Performance of a cylindrical diode array for use
in a 1.5 T MR-linac
, Phys Med Biol., 61(3), 2016, 80-89, DOI:
10.1088/0031-9155/61/3/N80.
17.
S.L. Hackett, B. van Asselen, J.W.H. Wolthaus:
Consequences of air
around an ionization chamber: are existing solid phantoms suitable
for reference dosimetry on an MR-linac?
, Med. Phys., 43, 2016, 3961.
18.
A. Syed Bilal, S. Arman, K. Anthony, M. Wronski, S. Arjun, B.M.
Keller:
Backscatter dose effects for high atomic number materials
being irradiated in the presence of a magnetic field: A Monte Car-
lo study for the MRI linac
, Medical Physics, 43, 2016, 4665, DOI:
10.1118/1.4955175.
19.
G.S. Ibbott, Y. Roed, H. Lee, M. Alqathami:
Gel dosimetry enab-
les volumetric evaluation of dose distributions from an MR-guided
linac
, AIP Conference Proceedings, 1747, 040002, 2016, DOI:
10.1063/1.4954102.
20.
D.J. O’BrienJ, D.A. Roberts, G.S. Ibbott, G.O. Sawakuchi:
Refe-
rence dosimetry in magnetic fields: formalism and ionization cham-
ber correction factors Source
, Med Phys., 43(8), 2016, 4915, DOI:
10.1118/1.4959785.
more than
peer-reviewed
scientific papers
Slip ring-based
gantry designed
for operation
in a magnetic
environment
Carefully shaped MR
field ensures critical
linac components are
positioned within an
area of low magnetic field
INTELLIGENT
SOFTWARE
Integrated workflow
for unprecedented
personalization
NEXT GENERATION
LINAC
With state-of-the-art,
160-leaf MLC
SLIP RING
TECHNOLOGY
Up to 6x faster gantry
rotation for continuous
treatment at any angle
SHORT, WIDE
BORE MAGNET
70 cm width bore
for patient comfort
*MRI technology partnership with Philips
®
. MR, magnetic resonance; MLC, multileaf collimator.
Elekta Unity is a work in progress and not available for sale. Reference: 1. Globocan 2012.
Art. No. LDMMRL170427 © 2017 Elekta AB (publ.) All mentioned trademarks and registered trademarks are the property of the Elekta Group.
All righ s reserved. No part of this d cument may be reproduced i any form without written permission from the copyright holder.
1.5T HIGH-FIELD
MR IMAGING*
For crystal clear
target visualization
Illustration 2 Black and White
Elekta Unity
1,2,3,4,5,6,7,8,9 11,12,13,14,15,16,17,18,19,20,...76
Powered by FlippingBook